Specification:

  • Complies with UL -864 and NFPA-72.
    20 x 4 Dot Matrix LCD Display.
    Operates on 120 – 220v 60 /50 Hz, AC Mains power supply.
    Standby (battery) backup 24v DC power supply with builtin charger.
    Touch Keypad for user friendly operation.
    Epoxy powder coated finish.
    Class- B, Style B / C initiating device circuit (IDC).
    All zones accept smoke detectors and any normally open contact device.
    Class B Notification Appliance Circuits (NAC).
    NAC shall be programmed as auto silence / Silence Inhibit.
    Error free Fire / Fault status in unambiguous colored LED indication.
    1000 Event storage with RTC.
    Main, Standby status with audible and visual indication.
    Two Form C relays for fire and fault.
    Resettable / Steady 24V D.C. Output.
    RS 485 Communication facility.
    TCP/IP facility (Optional)
    MODBUS for BMS integration (Optional).
    PC software (optional)
    External Zone Wise Sounder/Contact via RS 485 (Optional).
    All field wiring circuits are supervised.
    Zone Isolation facility with loop voltage cut off.
    Zones available : 12, 16, 20, 24, 32, 48, 64,96 and 128.
    Facility to connect Public Address System (PA) through RS-485 Communication.
    Peer to Peer network facility.
    Maximum 16 panels can be connect in a Single Network

  • ModelsDescriptionRE-900 SeriesFire Alarm Control PanelElectrical Specification
    Primary Power
    120 – 220VAC ± 10%, 60 / 50 Hz

  • .Initiating Device CircuitsAll zones are
    Class B Style B/C operation (Programmable).
    Normal Operating Voltage: 14 – 21 VDC.
    Alarm Current: 15 – 30mA.
    Short Circuit Current: 45mA Maximum.
    Loop resistance: 100 ohms Maximum.
    End-Of-Line Resistor: 4K7, 1/2watt
    Standby Current: 7mA (2.5mA for Detectors

  • )Standby Power
    24V D.C
    Quiescent current : 120 mA 

  • Operating Condition
    Operating Temperature 0 – 49° C/32-120° F.
    Relative Humidity 93 ± 2% RH (noncondensing)
    at 32 ±2° C/90 ±3° F. 

  • Charging Circuit
    Charging Voltage 28.0V, ±0.5V
    Charging Current 1.2A(Max)

  • Notification Appliance Circuits
    Class B Style – Y wiring
    Operating Nominal Voltage: 24VDC
    Special Application
    Current from 12 Zone Upto 64Zone
    NACs : 2 Amps (1 A per circuit)
    Current above 64Zone
    NACs : 4 Amps (1 A per circuit)
    Line Drop: 1.8V
    End-Of-Line Resistor: 4K7, 1/2watt

  • D.C. Output
    (Resettable / Steady)
    24VDC Output ,1A Max.

  • Common Relays
    Type   :   Form C
    No of Relays   :   2
    Relay Contact Rating   :   2Amps @ 30 VDC,
    0.5Amps @ 125VAC.
    Power Factor   :   1.0Dimensions
    Zones425HeightDepth12 Zone42535012016 Zone50035012020 Zone50060016024 Zone50060016032 Zone60060016048 Zone60070016064 Zone600100016096 Zone6001400160128 Zone6001400160All dimensions are in mm.Ordering Information
    ModelDescriptionRE-901212 Zone Fire Alarm Control PanelRE-901616 Zone Fire Alarm Control PanelRE-902020 Zone Fire Alarm Control PanelRE-902424 Zone Fire Alarm Control PanelRE-903232 Zone Fire Alarm Control PanelRE-904848 Zone Fire Alarm Control PanelRE-906464 Zone Fire Alarm Control PanelRE-909696 Zone Fire Alarm Control PanelRE-9128128 Zone Fire Alarm Control PanelCompatible Devices