Specification:
Complies with UL -864 and NFPA-72.
20 x 4 Dot Matrix LCD Display.
Operates on 120 – 220v 60 /50 Hz, AC Mains power supply.
Standby (battery) backup 24v DC power supply with builtin charger.
Touch Keypad for user friendly operation.
Epoxy powder coated finish.
Class- B, Style B / C initiating device circuit (IDC).
All zones accept smoke detectors and any normally open contact device.
Class B Notification Appliance Circuits (NAC).
NAC shall be programmed as auto silence / Silence Inhibit.
Error free Fire / Fault status in unambiguous colored LED indication.
1000 Event storage with RTC.
Main, Standby status with audible and visual indication.
Two Form C relays for fire and fault.
Resettable / Steady 24V D.C. Output.
RS 485 Communication facility.
TCP/IP facility (Optional)
MODBUS for BMS integration (Optional).
PC software (optional)
External Zone Wise Sounder/Contact via RS 485 (Optional).
All field wiring circuits are supervised.
Zone Isolation facility with loop voltage cut off.
Zones available : 12, 16, 20, 24, 32, 48, 64,96 and 128.
Facility to connect Public Address System (PA) through RS-485 Communication.
Peer to Peer network facility.
Maximum 16 panels can be connect in a Single Network
ModelsDescriptionRE-900 SeriesFire Alarm Control PanelElectrical Specification
Primary Power
120 – 220VAC ± 10%, 60 / 50 Hz.Initiating Device CircuitsAll zones are
Class B Style B/C operation (Programmable).
Normal Operating Voltage: 14 – 21 VDC.
Alarm Current: 15 – 30mA.
Short Circuit Current: 45mA Maximum.
Loop resistance: 100 ohms Maximum.
End-Of-Line Resistor: 4K7, 1/2watt
Standby Current: 7mA (2.5mA for Detectors)Standby Power
24V D.C
Quiescent current : 120 mAOperating Condition
Operating Temperature 0 – 49° C/32-120° F.
Relative Humidity 93 ± 2% RH (noncondensing)
at 32 ±2° C/90 ±3° F.Charging Circuit
Charging Voltage 28.0V, ±0.5V
Charging Current 1.2A(Max)Notification Appliance Circuits
Class B Style – Y wiring
Operating Nominal Voltage: 24VDC
Special Application
Current from 12 Zone Upto 64Zone
NACs : 2 Amps (1 A per circuit)
Current above 64Zone
NACs : 4 Amps (1 A per circuit)
Line Drop: 1.8V
End-Of-Line Resistor: 4K7, 1/2wattD.C. Output
(Resettable / Steady)
24VDC Output ,1A Max.Common Relays
Type : Form C
No of Relays : 2
Relay Contact Rating : 2Amps @ 30 VDC,
0.5Amps @ 125VAC.
Power Factor : 1.0Dimensions
Zones425HeightDepth12 Zone42535012016 Zone50035012020 Zone50060016024 Zone50060016032 Zone60060016048 Zone60070016064 Zone600100016096 Zone6001400160128 Zone6001400160All dimensions are in mm.Ordering Information
ModelDescriptionRE-901212 Zone Fire Alarm Control PanelRE-901616 Zone Fire Alarm Control PanelRE-902020 Zone Fire Alarm Control PanelRE-902424 Zone Fire Alarm Control PanelRE-903232 Zone Fire Alarm Control PanelRE-904848 Zone Fire Alarm Control PanelRE-906464 Zone Fire Alarm Control PanelRE-909696 Zone Fire Alarm Control PanelRE-9128128 Zone Fire Alarm Control PanelCompatible Devices