Specification:

  • Complies with UL -864 and NFPA-72.
    20 x 4 Dot Matrix LCD Display.
    Operates on 120 – 220v 60 /50 Hz, AC Mains power supply.
    Standby (battery) backup 24v DC power supply with builtin charger.
    Touch Keypad for user friendly operation.
    Epoxy powder coated finish.
    Class- B, Style B / C initiating device circuit (IDC).
    All zones accept smoke detectors and any normally open contact device.
    Class B Notification Appliance Circuits (NAC).
    NAC shall be programmed as auto silence / Silence Inhibit.
    Error free Fire / Fault status in unambiguous colored LED indication.
    1000 Event storage with RTC.
    Main, Standby status with audible and visual indication.
    Two Form C relays for fire and fault.
    Resettable / Steady 24V D.C. Output.
    RS 485 Communication facility.
    TCP/IP facility (Optional)
    MODBUS for BMS integration (Optional).
    PC software (optional)
    External Zone Wise Sounder/Contact via RS 485 (Optional).
    All field wiring circuits are supervised.
    Zone Isolation facility with loop voltage cut off.
    Zones available : 12, 16, 20, 24, 32, 48, 64,96 and 128.
    Facility to connect Public Address System (PA) through RS-485 Communication.
    Peer to Peer network facility.
    Maximum 16 panels can be connect in a Single Network.

  • ModelDescriptionRE-900RP SeriesFire Alarm Repeater PanelElectrical Specification
    Primary Power
    120 – 220VAC ± 10%, 60 / 50 Hz.

  • Initiating Device Circuits
    All zones are
    Class B Style B/C operation (Programmable).
    Normal Operating Voltage   :   14 – 21 VDC.
    Alarm Current   :   15 – 30mA.
    Short Circuit Current   :   45mA Maximum.
    Loop resistance   :   100 ohms Maximum.
    End-Of-Line Resistor   :   4K7, 1/2watt
    Standby Current   :   7mA (2.5mA for Detectors)

  • Standby Power
    24V D.C
    Quiescent current   :   120 mA 

  • Operating Condition
    Operating Temperature   :   0 – 49° C/32-120° F.
    Relative Humidity   :   93 ± 2% RH (non- condensing) at 32 ±2° C/90 ±3° F. Charging Circuit
    Charging Voltage   :   28.0V, ±0.5V
    Charging Current   :   1.2A(Max);

  • D.C. Output(Resettable / Steady)
    24VDC Output ,1A Max.

  • Common Relays
    Type   :   Form C
    No of Relays   :   2
    Relay Contact Rating   :   2Amps @ 30 VDC, 0.5Amps @ 125VAC.
    Power Factor   :   1.0

  • Notification Appliance Circuits
    Class B Style – Y wiring
    Operating Nominal Voltage   :    24VDC
    Special Application Current   :   from 12 Zone Upto 64Zone
    NACs   :   2 Amps (1 A per circuit) Current above 64Zone
    NACs   :   4 Amps (1 A per circuit)
    Line Drop   :   1.8V
    End-Of-Line Resistor   :   4K7, 1/2wattDimensions
    ZonesWidthHeightDepth12 Zone42535012016 Zone42535012020 Zone50060016024 Zone50060016032 Zone50060016048 Zone60070016064 Zone600100016096 Zone6001400160128 Zone6001400160Ordering Information
    ModelsDescriptionRE-901212 Zone Fire Alarm Control PanelRE-901616 Zone Fire Alarm Control PanelRE-902020 Zone Fire Alarm Control PanelRE-902424 Zone Fire Alarm Control PanelRE-903232 Zone Fire Alarm Control PanelRE-904848 Zone Fire Alarm Control PanelRE-906464 Zone Fire Alarm Control PanelRE-909696 Zone Fire Alarm Control PanelRE-9128128 Zone Fire Alarm Control PanelCompatible Devices