top of page

Hub Hybrid

Hub Hybrid
Hybrid security system control panel
Hub

Hub Hybrid
Hybrid security system control panel
Hub

Product warranty

One Year Warranty

Hub Hybrid

Specification:

Capacity

Ajax devices

up to 100

  • Wired and wireless devices in any proportion.

  • 5 range extenders max.

  • 10 sirens or keypads with a built-in siren max.

Cameras or DVRs

up to 25

  • RTSP support.

  • Seamless integration with the Dahua, Hikvision,

  • Safire, EZVIZ, Uniview IP cameras and DVRs.

Users

up to 50

  • Any number of admin users within the limit.

  • PRO accounts for installers and monitoring companies.

  • Access management for regular users.

Automation scenarios

up to 32

  • Alarm reactions.

  • Scheduled actions.

  • Security mode changing reactions.

  • Temperature changing reactions.

  • Humidity changing reactions.

  • Reactions to changes in COâ‚‚ concentration.

  • Reactions to pressing the Button.

Security groups

up to 9

Rooms

up to 50

Event log

up to 1000 events

Events are saved on the non-volatile onboard flash memory.

Wired communication

Fibra communication technology

Proprietary wired communication technology. Fibra combines the reliability of wires with the freedom of radio connection.

It features:

  • Two-way communication.

  • Advanced anti-sabotage.

  • Instant notifications.

  • Remote configuration via the Ajax apps.

Compatible wire

4–core cable

Bus connection.

Input

8 bus lines

Compatible with Fibra devices only.

Bus line length

up to 2.000 m

When using the U/UTP cat.5 twisted pair.

Calculate the line length at the facility

Power supply of devices

up to 14.4 W

For all connected wired devices.

Calculate the power supply of devices

Output voltage range

23–25.1 V⎓

Topologies

  • Star

  • Ring

In the line breakage event, the ring splits into two working segments, the devices continue to operate, and the system notifies a security company and users about the incident.

Devices polling interval

from 12 to 300 s

Adjusted by PRO or user with admin rights in the Ajax app.

Encrypted communication

Wireless communication

Jeweller communication technology

Proprietary wireless communication technology to transmit alarms and events.

It features:

  • Two-way communication.

  • Advanced anti-sabotage.

  • Block encryption featuring a dynamic key.

  • nstant notifications.

  • Remote configuration via the Ajax apps.

Frequency bands

866.0 – 866.5 MHz
868.0 – 868.6 MHz
868.7 – 869.2 MHz
905.0 – 926.5 MHz
915.85 – 926.5 MHz
921.0 – 922.0 MHz

Depends on the region of sales.

Maximum effective radiated power (ERP)

up to 20 mW

Featured automatic power control to reduce power consumption and noise interference.

Radio signal modulation

GFSK

Radio signal range

up to 2.000 m

Between the hub and connected devices (in an open space). Maximum range depends on the connected device.

Calculate radio signal range at the facility

Polling interval

from 12 to 300 s

Adjusted by PRO or user with admin rights in the Ajax app.

Encrypted communication

All the data stored and transmitted are protected by block encryption with a dynamic key.

Radio frequency hopping

Learn more

Wings communication technology

Proprietary wireless communication technology to transmit photo verifications.

It features:

  • Two-way communication.

  • Block encryption featuring a dynamic key.

  • Advanced anti-sabotage.

  • Package re-uploading in case of transmission errors.

  • Photo delivery check.

Frequency bands

866.0 – 866.5 MHz
868.0 – 868.6 MHz
868.7 – 869.2 MHz
905.0 – 926.5 MHz
915.85 – 926.5 MHz
921.0 – 922.0 MHz

Depends on the region of sales.

Radio signal range

up to 1.700 m

Between the hub and connected devices (in an open space). Maximum range depends on the connected device.

Calculate radio signal range at the facility

Radio frequency hopping

Radio communication uses frequency hopping to prevent interception and jamming.

Recommendations

100–240 V~ power supply. For indoor use only.

Communication channels

Ethernet

1 × 8P8C socket

Up to 100 Mbps.

Cellular

2 × micro–SIM slot

Cellular bands

2G

(GSM900/DCS1800 (B3/B8))

3G

(WCDMA 850/900/2100 (B1/B5/B8))

4G/LTE

(FDD B1/B3/B5/B7/B8/B20)

Automatic switching between communication channels

  • Switching between SIMs — up to 4 minutes.

  • Switching between 4G, 3G, and 2G networks of one SIM — instantly.

  • Switching between Ethernet and SIM — instantly.

Communication channels prioritization

1. Ethernet
2. Cellular connection

Communication channels work in parallel to increase system reliability. Most of the data is transmitted via Ethernet.

Alarm Transmission System Categories

SP2, SP5, DP3

Control panel operation method

Pass-through

Signaling security

S2

Substitution security.

Information security

I2

Encryption algorithm

AES 128

Supported notification types

  • Push

  • SMS

  • Calls

Event types

  • Alarms

  • Malfunctions

  • Events

  • Security mode changing

The notification types are configured individually for each user. Notifications could be customized for A–F schemes according to EN 50131 requirements.

Photo by alarm

  • Photo by scenario

  • Photo on demand

  • Photo by schedule

The Photo by Schedule feature is available for hubs with firmware version OS Malevich 2.19 or higher.

More about photo by scenario

More about photo on demand

More about photo by schedule

Photo delivery time

up to 9 s

by default.

Photo resolution

up to 640 × 480 pixels

Depends on the detector.

Number of photos in a series:

from 1 to 5 pictures

Monitoring

Supported protocols

  • SurGard (Contact ID)

  • SIA (DC-09)

  • Other proprietary protocols

Event types

  • System alarms and events

  • Photo verifications

  • Panic button coordinates

CMS software with photo verification support

Power supply

Main power supply type

Type A

Device operating AC voltage range

100–240 V~, 50/60 Hz

From the main power supply. Up to 10 W of mains power consumption.

Device operating DC voltage range

10.5–15 V⎓

From the backup battery (not included). Hub has space in the enclosure and rails for installing batteries with a capacity of 4, 7, or 9 Ah.

Autonomous operation

up to 60 hours

Hub Hybrid with a 7 Ah backup battery can power a system of 30 wired devices for 60 hours. Wireless devices operate on batteries and do not require additional power supply.

The Battery Power Saver feature allows extending the backup battery life.

Learn more

Low battery voltage

11.7 V⎓

Low battery recovery voltage

12.9 V⎓

End of life battery voltage

11 V⎓

Hub Hybrid is switched off.

Maximum output peak-to-peak ripple battery voltage

220 mV⎓

Minimum backup battery energy level in the charged state

100 %

Current consumption

Maximum rated output

0.53 A

Maximum at nominal voltage

200 mA

Quiescent at nominal voltage

130 mA

Average*

up to 93 mA

When GSM and Ethernet are enabled.

up to 72 mA

When Ethernet is disabled.

* From the backup battery after the loss of the main power supply.


bottom of page